Two options are available​

  • physical hosting per 'U' in a shared rack and shared space,
  • dedicated rack hosting of at least 42 'U' in shared space.

Supported Housing orders are accessible in the Orders (Order) module of the Cloud Temple console: space reservation, installation and un-racking, technical assistance, smart hands, and cabling/uncabling. For operations not supported by the console, contact support. The request must specify in particular:

Your Organization's name A contact name with their email and phone number to finalize the configuration The tenant name The desired hosting type (shared per 'U' or dedicated per rack) The desired quantity The equipment type and its specifications (size, weight, power consumption, heat dissipation, ...)

The Cloud Temple support team will contact you to finalize the request.

Shared hosting​

Appliance Hosting (réseau, firewall, ...)​

Shared hosting takes place in a rack shared among various Cloud Temple clients. La segmentation is done per 'U' (unité de rack). A rack unit measures 1.75 inches (44.45 mm) in height. Shared hosting racks are equipped with two separate power chains.

The maximum equipment weight per 'U' is 25 kg. Beyond that, you must order the number of 'U's required to support the total weight of your equipment.

For example, for equipment weighing 34 kg, you must order 2 rack units.

For each rack unit, you can request one or two C13 power outlets depending on your needs.

Each power outlet is limited to 150W at 220V per 'U'.

If you want your equipment to have a power capacity of 1500W across two power supplies, you must request

1500 W / 150 W = 10 'U', which means 5 'U' (or 750 W) per power chain.

Network connectivity must be subscribed to separately based on the expected port type and desired bandwidth. Here are the possible options per network port:

  • Copper 100MBps/1Gbps,
  • Fiber 1Gbps/10Gbps via an SFP module provided for Cloud Temple-side connectivity.

For these equipment units, cooling is necessarily done from the front of the rack to the back, and the appliance takes its network connectivity at the front of the rack.

Note: the minimum commitment is 12 months.

ReferenceUnitSKUCommitment
RACK HOSTING - 1 U Shared - 150W (1 C13)1 Ucsp:(region):hosting:shared:basic:v112 months
RACK HOSTING - 1 U Shared - 300W (2 C13)1 Ucsp:(region):hosting:shared:premium:v112 months

Server Hosting​

The 'Servers' work units are designed to accommodate server heat dissipation and provide rear network connectivity, simplifying maintenance operations and thus optimizing rack cooling.

They are mandatory for servers.

ReferenceUnitSKUCommitment
RACK HOSTING - 1 U Shared - Server - 400 W (2 C19)2 Ucsp:(region):hosting:shared:srv:basic:v112 months
RACK HOSTING - 1 U Shared - Server - 800 W (2 C19)2 Ucsp:(region):hosting:shared:srv:premium:v112 months

Dedicated Hosting​

Dedicated rack hosting is located in a shared hosting zone outside of secnumcloud. The dedicated hosting rack has a minimum dimension of 42 'U' or 42 rack units. The depth is 1200 millimeters, with 1000 millimeters usable for equipment. The width is 600 millimeters.

It is delivered with the necessary cooling, secured front and rear doors, and 3 Kw of power across 2 electrical chains of 16 amperes each.

Additional power increments of 2Kw can be requested. The maximum weight of equipment that can be integrated into the dedicated rack is 1000kg.

The rack is equipped with 'PDU' (unité de distribution d'énergie) tailored to the subscribed power capacity and monitored. There is one 'PDU' per electrical chain.

ReferenceUnitSKUCommitment
RACK HOSTING - 42U Dedicated Rack including 3Kw of power1 rack 42Ucsp:(region):hosting:dedicated:rack:v112 months
POWER - 2 Kw additional2 Kwcsp:(region):hosting:dedicated:rack:2kw:v112 months

Network connectivity for physical hosting​

Network connectivity must be subscribed to in addition to physical hosting, based on the expected port type and desired bandwidth. Here are the possible options per network port:

  • Copper 1Gbps,
  • Fiber 1Gbps/10Gbps via an SFP module provided for Cloud Temple side connectivity.

It is also possible to request connectivity in the meet-me room zone of the various datacenters to receive your operator connectivity. This connectivity must necessarily be fiber optic at speeds of 1Gbps or 10Gbps.

ReferenceUnitSKUCommitment
NETWORK - 1 port - 1 Gbps - fiber or copper1 portcsp:(region):hosting:shared:port1g:v136 months
NETWORK - 1 port - 10 Gbps - fiber1 portcsp:(region):hosting:shared:port10g:v136 months
NETWORK - Private link connection in an AZ meet-me room - 1 port 1Gbps1 packagecsp:(region):hosting:mmr:v1:1g36 months
NETWORK - Private link connection in an AZ meet-me room - 1 port 10Gbps1 packagecsp:(region):hosting:mmr:v1:10g36 months

'Hands & Eyes' Services​

In addition to physical hosting and network connectivity services, you can request professional assistance services for your physical hosting.

They are performed by datacenter technicians or Cloud Temple engineers specialized in datacenters.

Below are the main 'Hands & Eyes' service units available. They aim to address the following tasks:

  • Accompanying a previously identified external technician,
  • Checking equipment status (état des LEDS, état de fonctionnement, ...),
  • Taking photos of a previously identified customer equipment,
  • Pressing a switch,
  • Rebooting the equipment,
  • Connecting an access terminal for remote control,
  • Replacing cabling without modifying the existing wiring.
ReferenceUnitSKUGTI
Hand's & Eyes datacenter - Business Hours (8h - 19h; Lundi au vendredi)1 hourcsp:(region):hosting:ho:std:v12 hours
Hand's & Eyes datacenter - Business Hours (8h - 19h; Lundi au vendredi) - URGENT1 hourcsp:(region):hosting:ho:fast:v130 minutes
Hand's & Eyes datacenter - Non-Business Hours (nuit, week end et jours fériés)1 hourcsp:(region):hosting:hno:std:v12 days
Hand's & Eyes datacenter - Non-Business Hours (nuit, week end et jours fériés) - URGENT1 hourcsp:(region):hosting:hno:fast:v12 hours

You can also avail a Cloud Temple datacenter engineer to handle the following tasks:

  • Racking (avec les équipements de protection et de levage adaptés),
  • Cabling (suivant le plan de câblage préalablement remis),
  • Cabling modification or relocation of existing equipment,
  • Operator network connectivity assistance.
ReferenceUnitSKUGTI
Datacenter Engineer - Business Hours (8h - 19h; Lundi au vendredi)1 taskcsp:(region):hosting:ho:std:v12 days
Datacenter Engineer - Business Hours (8h - 19h; Lundi au vendredi) - URGENT1 taskcsp:(region):hosting:ho:fast:v14 hours

Note:

  • All requests must go through opening a ticket in the Cloud Temple console,
  • In case of an urgent request, call the on-call support after opening the ticket in the Cloud Temple console,
  • Any started hour is billable.